- SkyScan1178
- high-throughput micro-CT
<<< other direct links here |
|
-
World's first
dual source in-vivo micro-CT
-
- two
source / camera pairs to double scanning speed,
-
- full body
mouse scan in 25-40 seconds,
-
- fast
cluster reconstruction simultaneous with scanning,
-
-
interchangeable
bed holder to combine with PET, SPECT, and bioluminescence,
-
-
integrated physiological monitoring (breathing, movement detection, ECG)
and gating,
-
- software
for 2D/3D image analysis, bone morphometry and realistic visualization.
|
 |
|
-
The SkyScan 1178 is
a fast micro-CT scanner with a scanning + reconstruction cycle of less than
one minute for the entire volume. Static object position facilitates in-vivo
scanning of laboratory animals and industrial applications, such as quality
control and process monitoring.
High scan speed is achieved by means of two x-ray source-camera pairs,
doubling the acquisition rate. Networked cluster reconstruction allows
generation of datasets in less than the scan time, and the whole
scan-reconstruction cycle time can be less than one minute. Animal beds for
rats and mice made of carbon fiber are supplied on an interchangeable holder
to combine with PET, SPECT, and bioluminescence. A
physiological monitoring
subsystem can measure breathing and heartbeat in real time while also
providing signals for gated acquisition. The full range of SkyScan software
is supplied, including fast
volumetric reconstruction, software for
2D / 3D quantitative analysis and for realistic 3D
visualization.
Application examples: 
- Available software updates:
Control software
for SkyScan-1178
|
| home
|
|
physiological monitoring
all application examples
all software updates |
|
|
|
|
|
|
SPECIFICATIONS: |
|
|
|
X-ray source(s) ............. one
or two sealed metallo-ceramic tubes 20-65kV, 40W |
|
|
|
X-ray detector(s)............ one or
two digital X-ray cameras 1280x1024 pixels, 12bit |
|
|
|
Scanning volume ........... 82mm diam.,
82mm single scan length, 200mm full scan length |
|
|
|
Voxel size (isotropic) .... 80µm
(1024x1024x1024) or 160µm (512x512x512pixels) |
|
|
|
Min. scanning time ........ less than
40s (160µm), 1min 50s (80µm) for entire volume |
|
|
|
Reconstruction time ..... 45s
(160µm), 3min (80µm) for entire volume during acquisition |
|
|
|
Gating ............................
breathing, heartbeat (more
about physiological monitoring>) |
|
|
|
Radiation safety ........... <1µSv /
h at any point on the instrument surface during scan |
|
 |
| |