SkyScan1174 compact micro-CT
 
<<< other direct links here
 
World's most compact X-ray micro-CT
At a fraction of the price of competitive systems, with a small footprint, this system provides fast, high resolution 3D imaging.
  - 50kV maintenance-free X-ray source,
  - cooled 1.3 megapixel x-ray camera,
  - down to 6µm 3D spatial resolution,
  - scanning during compression, tension, cooling,
  - 2D/3D image analysis and realistic visualization.
 

 

This scanner uses an x-ray source with adjustable voltage and a range of filters for versatile adaptation to different object densities. A sensitive 1.3 megapixel x-ray camera allows scanning of your whole sample volume in several minutes. Variable magnification (6-30 µm pixel size) is combined with object positioning for easy selection of the object part to be scanned. The scanner can run from any desktop or portable computer, requiring just one USB (or serial) port and a FireWire (IEEE1394) input. The full range of SkyScan software is supplied, including fast volumetric reconstruction, software for 2D / 3D quantitative analysis and for realistic 3D visualization.

Application examples:

Available software updates:

 Control software ver.1.2 for SkyScan 1174

CTan ver.1.5.0 + CTvol ver 1.9.4 - 2D/3D image analysis and realistic visualization
  MTS50N ver.1.2 Material testing stage control program
   home      

 

   optional stages     all application examples      all software updates  
     
  SPECIFICATIONS:  
 

X-ray source ............ 20-50kV, 40W maximum power, filter holder for energy selection

 
  X-ray detector .......... 1.3Mp CCD coupled to scintillator by lens with 1:6 zoom range  
  Spatial resolution ..... 6...30 µm pixel size, approximately 10µm low-contract resolution  
  Object size ................ 5 - 30mm in diameter, 50mm in length (50mm vertical travel)  
  Reconstruction ......... single PC or cluster volumetric reconstruction (Feldkamp algorithm)  
  Optional stages ........ micropositioning, cooling, compression / extension / torsion (more>)  
  Radiation safety ....... <1µSv / h at any point on the instrument surface  
 
home
news
technology
contacts
 
products: 
 1172 hi-resolution 
 1173 high-energy 
 1176 in-vivo
 1178 fast
 2011 nano-ct
 2140 micro-XRF
 micro-CT for SEM
 optional stages
 physiol.monitoring
 reconstruction
 analysis,rendering
software updates
 
applications:
 biomedical
 material science
 electronics
 geology,diamonds
 wood, paper,...
 
distributors:
 SkyScan directly
 Europe
 America
 Middle East,Africa
 Asia
 Australia, NZ