SkyScan1172
  high-resolution micro-CT
 
<<< other direct links here
   
World's first 11 Megapixel micro-CT
  - fully distortion corrected 11Mp X-ray camera,
  - up to 8000x8000 pixels in every slice,
  - down to 0.7µm isotropic detail detectability,
  - dynamically variable acquisition geometry for shortest scan at any magnification,
  - single computer or cluster 3D reconstruction,
  - software for 2D / 3D image analysis, bone morphometry and realistic visualization
   

 

The innovative flexible geometry of the SkyScan 1172 scanner is particularly advantageous over intermediate resolution levels, where scans are several times faster (to obtain the same or better image quality) compared to micro-CT systems with a fixed source-detector design. The new large format cooled x-ray digital camera achieves high spatial resolution without compromising sample size. Fast scan and reconstruction throughput is supported by a computer cluster option, which reconstructs scan datasets in less time than the scan duration in most cases, using several PCs in parallel. Cross section images are generated in a wide range of formats up to 8k x 8k pixels. The full range of SkyScan software for 2D / 3D quantitative analysis and for realistic 3D visualization supplied with all scanners.

Application examples:

Available software updates:

Control software ver.1.5 for 1172/A (68mmFOV), 1172/B (37mm FOV), 1172/C (37mm FOV), 1172/D (50mm FOV)

CTan ver.1.5.0 + CTvol ver 1.9.4 - 2D/3D image analysis and realistic visualization
  MTS50N ver.1.2 Material testing stage control program
   home      

 

     optional stages    all application examples   all software updates  
     
  SPECIFICATIONS:  
 

X-ray source ................ 20-100kV,10W,<5µm spot size or 20-80kV, 8W, <8µm spot size

 
  X-ray detector ..............11Mp, 12-bit cooled CCD fiber-optically coupled to scintillator  
  Maximum object size... 27mm in diameter(single scan) or 50mm in diameter (offset scan)  
  Detail detectability ...... <0.8µm at highest resolution  
  Reconstruction ............ single PC or cluster volumetric reconstruction  
  Optional stages .......... micropositioning, cooling, compression / tension (more>)  
  Radiation safety ......... <1µSv / h at any point on the instrument surface  

 

 

 

 

 

 

 

 

 

microtomography, nanotomography, micro-CT, nano-ct, microCT, nanoct, mikroct, mikro-ct, mikro-computertomographie, microtomographie, small animal imaging, non-invasive, non-destructive, NDT, NDE, 3D microscopy,tomography, microscopy, 3D, three-dimensional, medical imaging, small animals, volume rendering, volume visualization
 

 

 

home
news
technology
contacts
 
products: 
 1272 hi-resolution
 1173 high-energy 
 1174 compact
 1176 in-vivo
 1178 fast
 2011 nano-ct
 2140 micro-XRF
 micro-CT for SEM
 optional stages
 physiol.monitoring
 reconstruction
 analysis,rendering
software updates
 
applications:
 biomedical
 material science
 electronics
 geology,diamonds
 wood, paper,...
 
distributors:
 SkyScan directly
 Europe
 America
 Middle East,Africa
 Asia
 Australia, NZ